CryoMagn OPT Print
  • Cryostat with superconducting magnet for optical studies

The cryostat CryoMagn Opt designed specially for optical studies in visible/UV/IR regions with superconducting “split-coil” magnets in Faraday or Voigt geometry has low helium consumption and reliable optical windows. The design of windows suggests that the optical channel is evacuated that prevents the perturbation of optical beam by boiling helium.

The built-in liquid helium level gauge and removable liquid helium transfer line provide the helium level monitoring and filling services.

The highly reliable superconducting solenoid with attachable copper or HTSC current leads is built by multifilament wire based on NbTi or Nb3Sn superconductors. The resistor/diode protection circuit secures the safety use of the superconducting solenoid. As an option,we supply a superconducting switch to maintain the superconducting short-cut regime and the electrical power supply for solenoid.

Basic parameters of the system

Central field at 4.2 K, T

5 – 8

Homogeneity in a 10 mm sphere near the center of solenoid, %

0.5 – 0.1

Maximum sweep rate, T·sec-1

0.01

Maximum current, A

100

Coil split, mm

14 – 24

Solenoid bore, mm

25 – 50

Helium reservoir capacity, l

15 – 25

Nitrogen reservoir capacity, l

12 – 18

Liquid helium consumption for cooling down to 4.2 K, l

30

Liquid helium consumption during operation, l/hour

0.3

Liquid helium consumption with removed current leads, l/hour

0.2

Cryostat overall height, mm

1300

Cryostat diameter, mm

350 – 420

Total weight of cryostat, kg

60

Complete system

  1. CryoMagn OPT cryostat.

  2. Built-in helium level sensor.

  3. Electronic unit for level monitoring.

  4. Variable length or flexible liquid helium transfer line.

Optionally

  1. Variable temperature insert INMAGN-115-1.4-He4 for temperature region 1.4 – 273 K with the temperature controller tSTAT310x and manostat.

  2. Sample holder.

Additional equipment

  1. Liquid nitrogen level indicator.

  2. Liquid nitrogen or helium storage vessels.

  3. Special type sample holders.

Key benefits

  • Low helium consumption.

  • High reliability.

  • Competitive price.

 
Postal address: RTI Ltd., Institutskaya str. b.2, 142432 Chernogolovka, Moscow region, Russian Federation