products
cryogenic
equipment
superconducting
magnets and accessoires
closed-cycle
cryogenic equipment
calibrated
temperature sensors
compact superconducting
tomograph
liquid nitrogen
production units
magnetic field
measurement (SENIS)
 
vacancies
 
« < April 2024 > »
M T W T F S S
1 2 3 4 5 6 7
8 9 10 11 12 13 14
15 16 17 18 19 20 21
22 23 24 25 26 27 28
29 30 1 2 3 4 5
CryoMagn 1-40-12 Print
  • Cryostat with superconducting magnet up to 12 Tesla at 4.2 K

The cryostat CryoMagn 1-40-12 with superconducting magnet designed for the studies of the superconductivity, the quantum Hall effect, magneto-optics investigations in magnetic field up to 12 T at 4.2 K. The cryostat allows the use of the variable temperature inserts for temperature region 0.3 – 273 K.

The design suggests location of the superconducting magnet in a completely welded liquid helium reservoir. Small opening for variable temperature inserts is compatible with the magnet bore. This minimizes the heat flow from the top flange to the helium reservoir. The copper shield attached to the bottom of the nitrogen reservoir and cooled by liquid nitrogen hangs over the cryostat to its bottom. The shielding reduces the helium boil-off and optimizes the consumption of cryogenic liquids. The built-in liquid helium level gauge and removable liquid helium transfer line provide the helium level monitoring and filling services.

The highly reliable superconducting solenoid with attachable copper or HTSC current leads is built by multifilament wire based on NbTi and Nb3Sn superconductors. The resistor/diode protection circuit secures the safety use of the superconducting solenoid. As an option, we supply a superconducting switch to maintain the superconducting short-cut regime and the electrical power supply for solenoid.

Basic parameters of the system

Central field at 4.2 K, T

8 – 12

Homogeneity in a 10 mm sphere near the center of solenoid, %

0.1

Maximum sweep rate, T·sec-1

0.01

Maximum current, A

250

Solenoid bore, mm

40

Helium reservoir capacity, l

20 – 30

Nitrogen reservoir capacity, l

18 – 22

Liquid helium consumption for cooling down to 4.2 K, l

30

Liquid helium consumption during operation, l/hour

0.3

Liquid helium consumption with removed current leads, l/hour

0.2

Cryostat overall height, mm

1350

Cryostat diameter, mm

380

Total weight of cryostat, kg

60

Complete system

  1. CryoMagn 1-40-12 cryostat.

  2. Built-in helium level sensor.

  3. Electronic unit for level monitoring.

  4. Variable length or flexible liquid helium transfer line.

Optionally

  1. Variable temperature insert INMAGN-115-1.4-He4 for temperature region 1.4 – 273 K with the temperature controller tSTAT310x and manostat.

  2. Variable temperature insert INMAGN-112-03-He3 for temperature region 0.3 – 1.4 K.

  3. Sample holder.

Additional equipment

  1. Liquid nitrogen level indicator.

  2. Liquid nitrogen or helium storage dewars.

  3. Special type sample holders.

Key benefits

  • Moderate helium consumption.

  • High reliability.

  • Competitive price.

 
Postal address: RTI Ltd., Institutskaya str. b.2, 142432 Chernogolovka, Moscow region, Russian Federation
Phone: +7 800 100-29-70